JZIKI Pulse Oximeter Fingertip Blood Oxygen Monitor|LED Display

Monitor your pulse rate and pulse oxygen saturation with the JZIKI Pulse Oximeter Fingertip Blood Oxygen Monitor with LED Display. It features a LED display, a PR Measuring range of up to 250bpm and an accuracy range of ±2% when Sp02 is between 70% and 100%.

SKU: JZK-301
R218,90 incl tax
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options

The Jziki Pulse Oximeter Fingertip Blood Oxygen Monitor with LED Display can be used to monitor the pulse oxygen saturation and pulse rate of someone through the fingertip. The device has an SpO2 accuracy rate of ±2% and can measure the blood oxygen saturation and pulse rate with high resolution. It also comes with a LED display for easy visual confirmation with options like an SPO2, PR digital display, and bar graph display to choose from. It also has low power consumption and can power off automatically when no signal is detected, is pretty small in size as well making it convenient to carry around. The finger oximeter is suitable for being used in the hospital, home, community medical treatment, sports healthcare, et cetera.

FEATURES:

  • Integrated with SPO2 probe and processing display module
  • An ideal range of applications (hospital, home, community medical treatment centers, sports healthcare, et cetera)
  • Can measure Blood oxygen saturation and Pulse rate accurately
  • SPO2, PR digital display and bar graph display
  • Oximeter battery voltage low indication
  • Low power consumption; power off automatically when no signal
  • Abnormal blood oxygen alarm
  • Convenient to carry

SPECIFICATIONS:

  • Display Mode: LED display
  • SpO2 Measuring Range: 0%~100% (resolution is 1%)
  • Accuracy between 70%~100% SpO2: ±2%
  • Accuracy below 70% SpO2: Unspecified
  • PR Measuring Range: 30bpm~250bpm (resolution is 1bpm)
  • Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when the pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger)
  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of the darkroom is less than ±1%
  • Power Consumption: less than 25mA
  • Voltage: DC 2.6V~3.6V
  • Power Supply: 1.5V x 2  (AAA size) alkaline batteries
  • Safety Type: Interior Battery, BF Type
  • Certificate: CE, RoHS, FDA, ISO9001, ISO13485
  • Dimensions: 5.8 × 3.3 ×3.2 cm

WHAT'S IN THE BOX:

  • Jziki Pulse Oximeter Fingertip Blood Oxygen Monitor with LED Display - White/Blue x1